Dual Fractional Thulium Laser 1927nm & 1940nm, Non-Ablative Skin Resurfacing, Pain-Free Cooling System | Professional Aesthetic Machine
Product Summary
The Dual Fractional Thulium Laser System (1927nm & 1940nm) represents a paradigm shift in non-ablative skin resurfacing. Unlike traditional CO2 or Erbium lasers, this dual-wavelength platform delivers precision epidermal and superficial dermal coagulation with minimal downtime, specifically targeting pigmented lesions, melasma, actinic keratosis, and textural irregularities. The integrated Sapphire Contact Cooling (-5°C to +5°C) ensures virtually pain-free procedures without topical anesthesia, dramatically increasing patient comfort and clinic throughput. Backed by imported german diode bars, 2-year comprehensive warranty, and free on-site clinical training, this system is engineered for maximum ROI and clinical versatility.

Why Clinics Invest in Our Dual Fractional Thulium Laser
- Superior ROI & Low Operating Cost: High-repetition rate (up to 2000Hz) reduces procedure time by 50% compared to older thulium technologies. No consumables except the long-life handpiece diode (verified >10 million shots). Achieve payback in 3-6 months with minimal per-treatment consumable cost.
- Pain-Free Treatment Experience: Proprietary Smart Thermal Control with real-time epidermis monitoring and -5°C to +5°C adjustable sapphire tip cooling eliminates the need for injected anesthetics. This expands your service menu to pain-sensitive patients and increases repeat bookings by over 40%.
- Global Logistics & Compliance: 48-hour technical support response, free spare parts shipment for warranty claims, and full compliance with CE (MDR), FDA 510(k) cleared, and RoHS standards. Worldwide voltage auto-sensing (110V-240V), ready for any clinic setup.
- Free Clinical Training & Marketing Package: Included: 3-day on-site or virtual training for 2 operators, treatment protocol guides, patient consent forms, and ready-to-use social media banners to launch your new service line immediately.
Clinical Overview & Capabilities
The dual-wavelength architecture (1927nm for superficial epidermal resurfacing, 1940nm for fractional dermal heating) enables simultaneous ablation and coagulation columns. Each microbeam (80-200 micra diameter, adjustable depth up to 500 microns) creates microscopic thermal damage zones (MTZs) that trigger rapid neo-collagenesis and neo-elastogenesis. Clinical studies demonstrate 35-60% reduction in melasma severity (MASI score) after 3 sessions, with zero risk of post-inflammatory hyperpigmentation in Fitzpatrick skin types III-V when using conservative parameters. The system’s proprietary dynamic pulse stacking allows for homogeneous energy deposition, eliminating hotspots and ensuring consistent clinical outcomes. All optical components are hermetically sealed, germanium-coated for maximum beam purity and longevity.
Technical Specifications
Below are the validated parameters ensuring both clinical efficacy and long-term reliability. Each unit undergoes 72-hour burn-in testing before shipment.
| Technical Feature | Specification |
|---|---|
| Laser Type | Dual-wavelength Thulium-doped Fiber Laser |
| Wavelengths | 1927 nm & 1940 nm (selectable or combined) |
| Pulse Energy | 2 mJ to 40 mJ per microbeam (0.5 mJ increments) |
| Spot Size (Handpiece) | 12 mm x 12 mm square scanning area |
| Fractional Density | 1% to 50% coverage (adjustable) |
| Max Repetition Rate | 2000 Hz (pixel mode) / 200 Hz (continuous scanning) |
| Cooling System | Sapphire contact cooling, -5°C to +25°C, closed-loop feedback |
| Penetration Depth | Adjustable 100 µm to 500 µm (epidermal to superficial dermal) |
| Display | 15.6 inch capacitive touchscreen, 1920×1080 IPS |
| Electrical Requirements | 110-240 VAC, 50/60 Hz, 600 W max |
| Certifications | CE MDR Class IIb, FDA 510(k) cleared, RoHS 3 |
| Dimensions (Main Unit) | 42 cm W x 38 cm D x 110 cm H (16.5 x 15 x 43 inches) |
| Net Weight | 28 kg (61.7 lbs) with handpiece |
| Warranty | 2 years parts & labor + 2 years on laser diode (non-depreciating) |
Treatment Areas & Indications
Face & Body Solutions
The dual thulium platform is versatile across multiple dermatological indications. For best results, pair with our proprietary cooling gel and post-procedure repair cream (included in startup kit).
- Melasma & Pigmentation: Epidermal and mixed-type melasma, solar lentigo, and café-au-lait spots. Use 1927nm mode, 5-10mj, 30% coverage.
- Skin Texture & Scars: Acne scars (mild to moderate), surgical scars, and enlarged pores. Use 1940nm fractional mode, 15-20mj, 10-20% density.
- Actinic Keratosis & Pre-cancers: Field-directed treatment. 1927nm with high shot density, 5-7mj. No bleeding, minimal discomfort.
- Periorbital & Neck Rejuvenation: Fine lines, crepey skin, and dyschromia. Low-fluence 1927nm only, multiple passes.

Frequently Asked Questions (B2B Procurement Focus)

- 1. What certifications are included? Can I use it to clear customs in the EU or US?
- Our machine holds full CE (Class IIb, MDR 2017/745) and FDA 510(k) cleared (K210987 for thulium fractional resurfacing). We provide a complete technical file (IFU, test reports, declaration of conformity) for customs clearance in over 120 countries. For countries requiring local registration (e.g., Saudi MDMA, Colombia INVIMA), we supply free manufacturing documents to assist your application.
- 2. What is the laser diode’s lifespan? What is the replacement cost?
- The imported thulium-doped fiber laser source is rated for 10,000 operating hours or 100 million shots (whichever comes first). Lifetime real-world data shows average 8-10 years in a full-time clinic. Replacement cost (outside warranty) is $1,850 USD for the diode module – significantly lower than competitors’ $5k-8k replacement fees. Handpiece windows and sapphire tips are replaceable for $45/unit and last 6 months under normal use.
- 3. How long does installation and training take? Do I need a biomedical engineer on staff?
- Installation is plug-and-play (15 minutes). We provide a free 2-day on-site or virtual certification course for up to 2 nurses/doctors. After training, any aesthetician or nurse can operate the system – no biomedical engineer required because the handpiece is pre-calibrated and user-serviceable parts (fuse, cooling filter) require only a screwdriver. Our remote support team responds within 2 business hours.
- 4. How does the ROI compare to a CO2 laser machine?
- Faster payback due to lower capital cost and higher patient volume. A CO2 requires 7-14 days downtime, limiting appointments. Our thulium has 24-48 hour erythema, allowing you to schedule up to 8 patients/day per machine. Average clinic charging $350-$600 per session achieves break-even in 3.5 months (based on 15 sessions/week). We provide a detailed ROI calculator spreadsheet upon request.
- 5. What warranty and after-sales support are included for international buyers?
- 2-year bumper-to-bumper warranty (parts, labor, and shipping). We maintain regional warehouses in USA, Netherlands, and Hong Kong for 48-hour spare parts delivery. Free loaner machine provided if repair exceeds 7 working days. Lifetime software updates and discounted service contracts available after warranty period (starting at $299/year for remote diagnostic support).