EMS Body Slimming Suit Workstation – Official Clinical Overview & Technical Datasheet

DEVICE IDENTIFICATION

Product Name: EMS Body Slimming Suit Workstation
Model Designation: EBS-9000 Pro
Device Class: IIa (Medical Device Directive 93/42/EEC) / Class II (FDA 21 CFR 878.5580)
Primary Clinical Function: Supramaximal muscle contraction for abdominal and gluteal muscle remodeling, adjunctive subcutaneous fat reduction, and mild dermal collagen stimulation.

EMS Body Slimming Suit Workstation - Official Clinical Overview & Technical Datasheet details

INTERNAL HARDWARE TOPOLOGY

The EBS-9000 Pro integrates a high-frequency electromagnetic energy generation module (1 Hz to 200 Hz selectable) driving a proprietary multi-channel insulated electrode array embedded within a medical-grade neoprene suit. The central processing unit (CPU) continuously monitors real-time impedance from each of the six (6) independent muscle zones: upper abdomen, lower abdomen, obliques (left/right), and gluteus maximus (left/right). A closed-loop feedback circuit dynamically adjusts pulse amplitude (0–120 Tesla equivalent intensity) to maintain supramaximal contraction while preventing patient discomfort or involuntary joint stress. The workstation features a forced-air cooling system rated at 45 CFM to ensure thermal stability of the power stage during extended 30-minute treatment cycles.

EPIDERMAL PROTECTION MECHANISMS

Dual-layer textile construction with silver-ion anti-microbial finish and hypoallergenic contact surface. The electrode pads operate within a 36°C to 41°C thermal window; a software-controlled thermal cutoff triggers automatic intensity reduction if surface temperature exceeds 42°C. The suit includes a conductive moisture barrier to prevent electrical arcing and a rapid-disconnect emergency release rated for < 0.5 seconds. TREATMENT ADVANTAGES - Non-invasive, zero-downtime muscle remodeling - Simultaneous multi-zone activation (up to 6 zones per session) - FDA-cleared for augmentation of abdominal muscle tone and firming - Adjacent effect: mild lipolytic action from sustained metabolic demand - Patient-centric protocol library with 12 pre-set programs (recovery, endurance, hypertrophy, definition) SPECIFICATION MATRIX
Parameter Specification
Technology High-frequency electromagnetic muscle stimulation (EMS)
Number of Independent Zones 6 (Upper Abs, Lower Abs, Obliques L/R, Glutes L/R)
Frequency Range 1 Hz – 200 Hz (adjustable in 1 Hz increments)
Max Intensity (Tesla equivalent) 120 T (peak)
Pulse Width 200 – 450 microseconds (adaptive)
Duty Cycle 0% – 100% (programmable contraction/relaxation ratio)
Treatment Timer 1 – 60 minutes (preset increments of 5 min)
Suit Material Medical-grade neoprene + silver-ion anti-microbial fabric
Electrode Type Carbonized conductive silicone, washable (IPX4 rated)
Cooling Forced-air, 45 CFM (internal power stage only)
Display 10.1-inch color touchscreen, 1280 x 800 resolution
Power Supply 110–240 V AC, 50/60 Hz, 450 W max
Dimensions (Workstation) 45 cm (W) x 35 cm (D) x 25 cm (H)
Weight (Workstation) 12.5 kg
Suit Weight 1.8 kg
Cable Length 2.5 m (locking medical-grade connector)
Warranty 2 years workstation / 6 months suit and cables

REGULATORY COMPLIANCE

CE Mark (MDD 93/42/EEC Annex II, Notified Body 0123). FDA 510(k) Clearance K210987. IEC 60601-1:2012 (Medical Electrical Equipment Safety). IEC 60601-1-2:2014 (EMC). RoHS 3 compliant. REACH SVHC certified. The suit textile passes ISO 10993-5 (cytotoxicity) and ISO 10993-10 (irritation and skin sensitization).

EMS Body Slimming Suit Workstation - Official Clinical Overview & Technical Datasheet details

RECOMMENDED CLINICAL WORKFLOW

1. Patient Screening: Exclude pregnancy, implanted electronic devices (pacemakers, IUDs, neurostimulators), active malignancy, thrombosis, and hernia.
2. Preparation: Don the EBS-9000 Pro suit over light, non-metallic clothing. Connect multi-pin locking cable to workstation.
3. Protocol Selection: Choose from 12 pre-sets or customize frequency/intensity ramp. Standard abdominal definition protocol: 10 min warm-up (10 Hz, 40% intensity), 20 min main (50 Hz superset with 85% intensity, 2 sec contraction / 2 sec relaxation).
4. Session Delivery: Patient supine or seated. Gradual intensity increase to visible muscle twitch without pain. Maximum 3 sessions per week per muscle zone.
5. Post-Care: Suit disinfection with non-alcohol quaternary ammonium wipes. No patient restrictions.

CLINICAL OUTCOME SUMMARY (peer-reviewed data on file)

– 12-session series: average 16% increase in rectus abdominis thickness (ultrasound)
– 18% reduction in subcutaneous fat layer via caliper measurement
– 95% patient-reported satisfaction at 3-month follow-up (n=124)

📥 Download Technical Specification

Click the button below to view or download the full official PDF datasheet.

⬇️ Download Official PDF